Fire Rated Walls in South Shields
Need a 30 or 60 minute wall in South Shields? Our vetted installers cover homes and businesses throughout South Tyneside.
Where we work around South Shields
South Shields is in the South Tyneside council area in the North East. That includes the NE34, NE33 and NE32 postcode districts. Nearby places we also cover include South Tyneside, Cleadon, East Boldon and West Boldon.
Fire Rated Walls in South Shields: local know-how
The North East has a high share of terraced and colliery-era housing, with modern estates growing around its larger towns. Victorian homes in South Shields often have lath and plaster walls that need assessing or overboarding to achieve 30 minutes. Holiday lets near South Shields split into multiple units often need fire separation between them.
Rear extensions in South Shields often include steel beams that need boxing in fire-resisting board. Suburban homes around South Shields with open-plan conversions may need alternative fire strategies agreed with Building Control.
What we can do in South Shields
Structural Steel Fire Protection
Boxing in steel beams and columns with fire-resisting board, or applying intumescent paint, to give 30 or 60 minutes protection.
Garage and Kitchen Separation Walls
Fire-resisting walls and ceilings between integral garages and the home, and around open-plan layouts where required.
Loft Conversion Fire Protection
Creating a protected stairway with 30 minute walls and fire doors so a loft conversion meets Building Regulations.
Fire Stopping and Penetration Sealing
Sealing every pipe, cable and duct that passes through a fire rated wall or floor with tested fire-stopping products.
Fire Rated Stud Partitions
New metal or timber stud walls built to tested 30, 60 or 120 minute systems using fire-resisting plasterboard.
HMO and Commercial Compartment Walls
Upgrading walls between bedrooms, flats, escape routes and commercial units to the fire resistance required by fire strategies.
Typical costs in South Shields
- Upgrade existing wall to 30 minutes: £35–£65 per m². Overboarding an existing sound wall with fire-resisting plasterboard and sealing edges.
- Loft conversion stair protection: £900–£2,500. Upgrading stair and landing walls to 30 minutes, excluding fire doors and alarms.
- Steel beam boxing: £250–£600 per beam. Boxing a typical domestic steel beam in fire-resisting board for 30 or 60 minutes.
Prices are a guide. Your quote for South Shields is a fixed price based on the details you give us. Full price guide.
Fire Rated Walls questions from South Shields
Will you provide records for Building Control in South Shields?
Yes. Installers in South Shields name the tested system used and provide photos of board layers and fire stopping, which helps sign-off by Building Control.
How long does fire rated wall work take in South Shields?
Most domestic fire rated walls in South Shields take one to three days. Loft stair protection takes two to five days, and commercial projects vary with size and access.
Can you upgrade HMO walls in South Shields?
Yes. HMO landlords in South Shields use our network to upgrade walls onto escape routes, fit fire stopping and meet licensing or fire risk assessment requirements.
Do you cover areas near South Shields?
Yes. We arrange fire rated walls in South Shields and nearby places including Jarrow and Tynemouth, through specialists who work across South Tyneside.
What is fire stopping?
Fire stopping is the sealing of gaps and service penetrations through fire rated walls and floors so fire and smoke cannot pass through. Products include intumescent sealants, pipe collars and wraps, fire batts and putty pads. Each must be installed to its tested detail to keep the wall's rating intact.
Does the wall between a garage and house need to be fire rated?
Yes. Building Regulations guidance requires an integral or attached garage to be separated from the house by fire-resisting construction, typically 30 minutes for the wall and any ceiling between. A connecting door should be a self-closing fire door, and pipes or cables through the wall must be fire stopped.
Helpful guides
Integral Garage Fire Separation: Walls, Doors and Ceilings
The walls and ceiling between an integral or attached garage and the house should provide fire resistance, typically 30 minutes, with any…
Read the guide →Loft Conversion Fire Protection: What the Rules Require
When a loft conversion adds a new storey to a typical house in England, Approved Document B normally requires a protected escape route from…