Creating a protected stairway with 30 minute walls and fire doors so a loft conversion meets Building Regulations.

Free Fire Rated Walls quote

No obligation. We only use your details to reply about this job.

Loft Conversion Fire Protection — Fire Rated Walls

What's involved

When a two-storey house gains a loft room, the escape route from the new floor usually has to be protected all the way to the front door. That typically means walls enclosing the stair and landing achieve 30 minutes fire resistance, doors onto the stair are replaced with FD20 or FD30 fire doors or upgraded, and interlinked mains smoke alarms are fitted. The installer checks existing walls, adds layers of fire-resisting plasterboard where needed, and closes off any openings into the stairway such as glazed panels or hatches. Lath and plaster walls in good condition may already perform, but often need overboarding. The work takes two to five days depending on the house. You need to have your Building Control approval or plans available so the specified fire strategy is followed.

How we handle it

  1. Tell us the requirement

    Use the quote form to describe the building, the wall's purpose and the fire rating required. Drawings, Building Control notes or a fire risk assessment help us brief the right specialist.

  2. Survey and specification

    A local specialist surveys the existing construction, confirms the rating and selects a manufacturer's tested system. You receive a fixed written price.

  3. Install the wall system

    Studs, track and fire-resisting board are installed to the system sheet, with correct layers, screw centres, mineral wool and deflection heads.

  4. Fire stop penetrations

    Every pipe, cable and duct through the wall is sealed with tested fire-stopping products, labelled and photographed for the record.

  5. Record and hand over

    Joints are finished, and you receive details of the systems used plus photographic records to support Building Control or your fire risk assessment.

Price guide

Fire rated wall prices depend on the rating required, the wall area, how many penetrations need fire stopping and whether existing walls are being upgraded or new ones built. Higher ratings need more layers of board and more labour. Every quote is fixed after a survey and names the tested system to be used.

  • Fire stopping penetrations: from £25 per penetration. Collars, sealant, batts or wraps depending on pipe, cable or duct size.
  • Steel beam boxing: £250–£600 per beam. Boxing a typical domestic steel beam in fire-resisting board for 30 or 60 minutes.
  • Loft conversion stair protection: £900–£2,500. Upgrading stair and landing walls to 30 minutes, excluding fire doors and alarms.

Questions about loft conversion fire protection

Does a loft conversion need fire rated walls?

In most two-storey houses, adding a loft room means the stairway must be protected to the exit, typically with 30 minute fire-resisting walls, fire doors onto the stair and interlinked smoke alarms. Some layouts use alternative solutions such as sprinklers, agreed with Building Control. Your approved plans will set out what is needed.

Do steel beams need fire protection?

In most homes, structural steel beams and columns need fire protection, typically 30 minutes, so they keep supporting the building during a fire. This is usually done by boxing the steel with fire-resisting plasterboard or applying intumescent paint. Your engineer or Building Control will confirm the requirement.