Fire Rated Walls

Edinburgh · Scotland

Fire Rated Walls in Edinburgh

We arrange fire rated walls and fire stopping in Edinburgh, using passive fire specialists across Edinburgh.

Find a vetted fire rated wall installer in Edinburgh.

Free Fire Rated Walls quote in Edinburgh

No obligation. We only use your details to reply about this job.

Covering Edinburgh and nearby

Edinburgh is in the Edinburgh council area in Scotland. Postcodes we cover here include EH4, EH14, EH12, EH6, EH16 and EH10.

What to expect in Edinburgh

HMOs in Edinburgh frequently need walls onto escape corridors upgraded to meet licensing conditions. Mixed-use buildings in central Edinburgh often need 60 minute separation between shops and the flats above.

Scotland's towns have a lot of sandstone and granite buildings, tenement flats and harled houses, with Scottish building standards rather than English Building Regulations applying. Older Edinburgh houses converted into flats frequently need compartment walls and floors improved. Fire rated construction in Edinburgh must meet Section 2 (Fire) of the Scottish Building Standards, usually under a building warrant from Edinburgh.

Fire Rated Walls prices in Edinburgh

  • Fire stopping penetrations: from £25 per penetration. Collars, sealant, batts or wraps depending on pipe, cable or duct size.
  • Steel beam boxing: £250–£600 per beam. Boxing a typical domestic steel beam in fire-resisting board for 30 or 60 minutes.
  • Loft conversion stair protection: £900–£2,500. Upgrading stair and landing walls to 30 minutes, excluding fire doors and alarms.

Prices are a guide. Your quote for Edinburgh is a fixed price based on the details you give us. Full price guide.

Fire Rated Walls questions from Edinburgh

How do I get a fire rated wall quote in Edinburgh?

Use our quote form with your Edinburgh postcode, the wall's purpose, size and required rating. Drawings or Building Control notes help. A specialist will give you a fixed price.

Can you fire stop penetrations in Edinburgh?

Yes. Specialists in Edinburgh seal pipes, cables and ducts through fire rated walls with tested collars, sealants and batts, and provide photographic records for your files.

Can you upgrade HMO walls in Edinburgh?

Yes. HMO landlords in Edinburgh use our network to upgrade walls onto escape routes, fit fire stopping and meet licensing or fire risk assessment requirements.

Does my Edinburgh garage wall need to be fire rated?

If your garage is integral or attached, the wall and ceiling between it and your Edinburgh home should be fire-resisting, typically 30 minutes, with a self-closing fire door.

Can I put a socket in a fire rated wall?

Yes, but the socket box breaks the fire-resisting board, so it must be protected. Common methods are intumescent putty pads behind the box or tested fire-rated back boxes. Back-to-back sockets should be offset. Without this, a socket can become a weak point where fire passes through the wall.

Does a loft conversion need fire rated walls?

In most two-storey houses, adding a loft room means the stairway must be protected to the exit, typically with 30 minute fire-resisting walls, fire doors onto the stair and interlinked smoke alarms. Some layouts use alternative solutions such as sprinklers, agreed with Building Control. Your approved plans will set out what is needed.

Get a free fire rated walls quote in Edinburgh

Tell us what you need and we'll come back with a clear price.

Request a quote