Fire Rated Walls glossary

The terms you'll come across, explained in plain English.

BS EN 13501-2
The European standard used in the UK to classify fire resistance of building elements, giving ratings such as EI 30 or REI 60.
Cavity barrier
A fire-resisting barrier fitted within a concealed space, such as a ceiling void or wall cavity, to stop fire and smoke spreading unseen.
Compartment wall
A fire resisting wall that separates one fire compartment from another, such as between flats or between parts of a commercial building.
Compartmentation
Dividing a building into fire-resisting sections using walls and floors, so fire and smoke are contained in one area for a set period.
FD30 fire door
A fire door set tested to provide 30 minutes of integrity. FD30s indicates it also has smoke seals. FD60 provides 60 minutes.
Fire collar
A steel collar containing intumescent material fitted around plastic pipes. In fire, it expands and crushes the softened pipe to close the hole.
Fire resistance
The ability of a wall, floor or door to resist fire for a set period in a standard test, keeping its strength, stopping flames and limiting heat transfer.
Fire stopping
Sealing gaps and penetrations in fire resisting walls and floors with tested products so fire and smoke cannot pass through around services.
Fire-resistant plasterboard
Plasterboard with glass fibres and additives in the core that help it stay intact in fire. Usually coloured pink or red and used in tested wall systems.
Insulation (fire)
The part of fire resistance that measures how long the unexposed side stays below set temperature limits. Shown as I in classifications such as EI 60.
Integrity
The part of fire resistance that measures how long a wall or door prevents flames and hot gases passing through cracks or openings. Shown as E in classifications.
Intumescent
A material that swells when heated, sealing gaps around services or doors. Used in sealants, strips, collars, wraps and pillows.
Protected stairway
A stair enclosed by fire resisting walls and doors so it remains a safe escape route for a set time during a fire.
Responsible person
Under the Regulatory Reform (Fire Safety) Order 2005, the person in control of premises, such as the employer or owner, who must manage fire safety.
Structural soffit
The underside of the floor slab or roof structure above. Fire rated walls usually need to run up to it rather than stopping at a suspended ceiling.