Fire Rated Walls
Fire Stopping and Penetration Sealing
Sealing every pipe, cable and duct that passes through a fire rated wall or floor with tested fire-stopping products.

What's involved
A fire rated wall is only as good as its weakest hole. Every pipe, cable tray, duct and socket box that passes through it must be fire stopped. The installer selects tested products to suit each penetration: intumescent sealant for small gaps, intumescent pipe collars or wraps for plastic pipes that melt and leave a hole in a fire, fire batts coated with ablative coating for large service openings, and fire-rated putty pads behind sockets. Each seal is installed to the product's tested detail, labelled where required and photographed. Fire stopping is commonly the item that fails inspection on refurbishments. Small jobs take a few hours; a commercial riser can take days. You need to provide access to ceiling voids and risers and let other trades finish running services first.
How we handle it
Tell us the requirement
Use the quote form to describe the building, the wall's purpose and the fire rating required. Drawings, Building Control notes or a fire risk assessment help us brief the right specialist.
Survey and specification
A local specialist surveys the existing construction, confirms the rating and selects a manufacturer's tested system. You receive a fixed written price.
Install the wall system
Studs, track and fire-resisting board are installed to the system sheet, with correct layers, screw centres, mineral wool and deflection heads.
Fire stop penetrations
Every pipe, cable and duct through the wall is sealed with tested fire-stopping products, labelled and photographed for the record.
Record and hand over
Joints are finished, and you receive details of the systems used plus photographic records to support Building Control or your fire risk assessment.
Price guide
Fire rated wall prices depend on the rating required, the wall area, how many penetrations need fire stopping and whether existing walls are being upgraded or new ones built. Higher ratings need more layers of board and more labour. Every quote is fixed after a survey and names the tested system to be used.
- 60 minute stud partition: £75–£120 per m². Two layers of fire-resisting board each side with mineral wool where specified.
- 30 minute stud partition: £55–£85 per m². Metal stud with fire-resisting board each side, taped and filled, typical domestic build.
- Fire stopping penetrations: from £25 per penetration. Collars, sealant, batts or wraps depending on pipe, cable or duct size.
Questions about fire stopping and penetration sealing
What is fire stopping?
Fire stopping is the sealing of gaps and service penetrations through fire rated walls and floors so fire and smoke cannot pass through. Products include intumescent sealants, pipe collars and wraps, fire batts and putty pads. Each must be installed to its tested detail to keep the wall's rating intact.
Other services
Fire Rated Stud Partitions
New metal or timber stud walls built to tested 30, 60 or 120 minute systems using fire-resisting plasterboard.
Loft Conversion Fire Protection
Creating a protected stairway with 30 minute walls and fire doors so a loft conversion meets Building Regulations.
Garage and Kitchen Separation Walls
Fire-resisting walls and ceilings between integral garages and the home, and around open-plan layouts where required.
Structural Steel Fire Protection
Boxing in steel beams and columns with fire-resisting board, or applying intumescent paint, to give 30 or 60 minutes protection.
HMO and Commercial Compartment Walls
Upgrading walls between bedrooms, flats, escape routes and commercial units to the fire resistance required by fire strategies.
Fire Stopping and Penetration Sealing near you
Get a free fire rated walls quote
Tell us what you need and we'll come back with a clear price.