What is a fire rated wall?

A fire rated wall is a wall built to resist fire for a set time, such as 30, 60 or 120 minutes, measured in standard fire tests. It must keep its stability, stop flames and hot gases passing through, and limit temperature rise on the safe side. The rating only applies if the wall matches the tested system exactly.

How much does a fire rated wall cost?

A 30 minute metal stud partition typically costs £55 to £85 per square metre, and a 60 minute partition £75 to £120 per square metre. Upgrading an existing wall to 30 minutes with extra board costs around £35 to £65 per square metre. Fire stopping penetrations starts from about £25 each.

What plasterboard is used for fire rated walls?

Fire rated walls use fire-resisting plasterboard, usually pink or red, which contains glass fibres and additives that help the board hold together in a fire. Typical thicknesses are 12.5 and 15 mm. Standard plasterboard offers some resistance but is not used where a specific rating is required, because tested systems specify fire-resisting board.

How do you make a wall 60 minutes fire rated?

A 60 minute wall is usually achieved with metal or timber studs boarded with two layers of fire-resisting plasterboard on each side, sometimes with mineral wool in the cavity. The exact build, including stud size, board thickness and screw spacing, must follow a manufacturer's tested system. Penetrations must be fire stopped to the same rating.

Does a loft conversion need fire rated walls?

In most two-storey houses, adding a loft room means the stairway must be protected to the exit, typically with 30 minute fire-resisting walls, fire doors onto the stair and interlinked smoke alarms. Some layouts use alternative solutions such as sprinklers, agreed with Building Control. Your approved plans will set out what is needed.

Does the wall between a garage and house need to be fire rated?

Yes. Building Regulations guidance requires an integral or attached garage to be separated from the house by fire-resisting construction, typically 30 minutes for the wall and any ceiling between. A connecting door should be a self-closing fire door, and pipes or cables through the wall must be fire stopped.

What is fire stopping?

Fire stopping is the sealing of gaps and service penetrations through fire rated walls and floors so fire and smoke cannot pass through. Products include intumescent sealants, pipe collars and wraps, fire batts and putty pads. Each must be installed to its tested detail to keep the wall's rating intact.

Do steel beams need fire protection?

In most homes, structural steel beams and columns need fire protection, typically 30 minutes, so they keep supporting the building during a fire. This is usually done by boxing the steel with fire-resisting plasterboard or applying intumescent paint. Your engineer or Building Control will confirm the requirement.

Can you upgrade an existing wall to be fire rated?

Often, yes. An existing stud or masonry wall can be upgraded by adding layers of fire-resisting plasterboard to a tested overboarding system and sealing all gaps and penetrations. The specialist checks the existing construction first, as damaged or unknown walls may need lining with an independent fire rated frame instead.

How long does it take to build a fire rated wall?

A typical domestic fire rated partition takes one to three days including taping and filling. Loft stair protection takes two to five days. Commercial compartment walls and remedial fire stopping can take from a few days to several weeks depending on size, access and whether the building stays occupied.

Who needs a fire risk assessment?

Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person for non-domestic premises, and for the common parts of blocks of flats and HMOs, must carry out a fire risk assessment. It often identifies walls, doors and fire stopping that need upgrading. Private single homes are not covered by the Order.

Can I put a socket in a fire rated wall?

Yes, but the socket box breaks the fire-resisting board, so it must be protected. Common methods are intumescent putty pads behind the box or tested fire-rated back boxes. Back-to-back sockets should be offset. Without this, a socket can become a weak point where fire passes through the wall.

Get a free fire rated walls quote

Tell us what you need and we'll come back with a clear price.