Houses in multiple occupation, flats above shops and commercial premises often need walls upgraded to meet a fire risk assessment or licensing requirement. Typical work includes upgrading bedroom walls onto escape corridors to 30 minutes, separating commercial units from residential floors to 60 minutes, and making good holes left by previous trades. The installer surveys the existing construction, proposes a tested upgrade such as overboarding or building an independent fire rated lining, and fire stops penetrations. Above suspended ceilings, compartment walls must continue up to the structural soffit, and cavity barriers may be needed. Work is often phased to keep buildings occupied. Durations range from a day to several weeks. You need to share the fire risk assessment or fire strategy so the specified ratings are met.

How we handle it

  1. Tell us the requirement

    Use the quote form to describe the building, the wall's purpose and the fire rating required. Drawings, Building Control notes or a fire risk assessment help us brief the right specialist.

  2. Survey and specification

    A local specialist surveys the existing construction, confirms the rating and selects a manufacturer's tested system. You receive a fixed written price.

  3. Install the wall system

    Studs, track and fire-resisting board are installed to the system sheet, with correct layers, screw centres, mineral wool and deflection heads.

  4. Fire stop penetrations

    Every pipe, cable and duct through the wall is sealed with tested fire-stopping products, labelled and photographed for the record.

  5. Record and hand over

    Joints are finished, and you receive details of the systems used plus photographic records to support Building Control or your fire risk assessment.

Price guide

Fire rated wall prices depend on the rating required, the wall area, how many penetrations need fire stopping and whether existing walls are being upgraded or new ones built. Higher ratings need more layers of board and more labour. Every quote is fixed after a survey and names the tested system to be used.

  • Loft conversion stair protection: £900–£2,500. Upgrading stair and landing walls to 30 minutes, excluding fire doors and alarms.
  • Steel beam boxing: £250–£600 per beam. Boxing a typical domestic steel beam in fire-resisting board for 30 or 60 minutes.
  • Fire stopping penetrations: from £25 per penetration. Collars, sealant, batts or wraps depending on pipe, cable or duct size.

Questions about hmo and commercial compartment walls

What plasterboard is used for fire rated walls?

Fire rated walls use fire-resisting plasterboard, usually pink or red, which contains glass fibres and additives that help the board hold together in a fire. Typical thicknesses are 12.5 and 15 mm. Standard plasterboard offers some resistance but is not used where a specific rating is required, because tested systems specify fire-resisting board.

Does a loft conversion need fire rated walls?

In most two-storey houses, adding a loft room means the stairway must be protected to the exit, typically with 30 minute fire-resisting walls, fire doors onto the stair and interlinked smoke alarms. Some layouts use alternative solutions such as sprinklers, agreed with Building Control. Your approved plans will set out what is needed.

Get a free fire rated walls quote

Tell us what you need and we'll come back with a clear price.

Request a quote