Guide · Businesses · 3 min read · Updated 17 November 2026
What Is Fire Stopping? Penetrations, Products and Rules
Short answer
Fire stopping is the sealing of gaps and openings in fire resisting walls and floors, such as holes around pipes, cables and ducts, so fire and smoke cannot pass through. It uses tested products including intumescent sealants, fire collars, wraps, batts and pillows, installed exactly as the product's approval specifies. Fire stopping penetrations typically cost from £25 each, depending on size and access.
Why fire stopping matters
A fire rated wall or floor is designed to hold back fire for a set period, typically 30, 60 or 120 minutes. As soon as a hole is cut for a pipe, cable tray or duct, that performance is compromised. Fire and smoke can pass through even a small gap far faster than through the wall itself. Plastic pipes melt quickly and leave an open hole.
Fire stopping restores the fire resistance of the wall or floor around each penetration. It is a vital part of compartmentation, the principle of dividing a building into sections that contain fire. Many fire risk assessments find missing or poor fire stopping, often caused by later trades running new services through walls and leaving the holes unsealed.
Common fire stopping products
Different penetrations need different products. Each product is tested in particular wall and floor types, with particular services and gap sizes, and must be used within that scope.
| Product | Used for | How it works |
|---|---|---|
| Intumescent sealant | Small gaps around cables and metal pipes | Expands with heat to fill the gap |
| Fire collar | Plastic pipes through walls and floors | Steel collar with intumescent core crushes the softened pipe |
| Fire wrap | Plastic pipes and insulated pipes | Intumescent strip wrapped round the pipe |
| Fire batt | Larger openings with multiple services | Coated mineral wool board cut to fit |
| Fire pillows | Cable trays and openings needing future access | Intumescent bags packed into the opening |
| Acrylic fire sealant | Linear gaps and joints | Fire-rated sealant for joints and small gaps |
How fire stopping is installed
A competent installer starts by identifying the fire rating of the wall or floor and the type of each service passing through. They then choose a product that has been tested for that combination, check the gap size against the product's limits, and install it exactly as the manufacturer specifies, for example with the right depth of sealant, the right size of collar and the right fixings.
Each completed penetration is usually labelled and photographed, with a record of the product used and the fire rating achieved. That evidence is important for building control, fire risk assessors and future maintenance, because it is often impossible to tell what was used once a seal is painted or hidden behind a ceiling.
- Identify the wall or floor fire rating
- Identify each service: material, size and insulation
- Select a product tested for that combination
- Check gap size is within the product's limits
- Install to the manufacturer's instructions
- Label, photograph and record each penetration
Common fire stopping mistakes
The most common mistake is using expanding foam that is not fire-rated, or ordinary sealant, to fill holes around services. Even fire-rated foam is only suitable within its tested scope. Another frequent problem is mixing products, for example putting a fire collar on one side of a wall but not the other when the test required both. Over-sized holes, where a large opening has been cut for a single small pipe, often exceed the limits of the product used.
Cables bundled tightly through a hole with sealant only around the outside leave voids in the middle. Fire batts that have been cut to fit and not properly coated at the edges let smoke through. Later trades who cut through a sealed penetration to add a cable and do not reinstate it are another major cause.
Legal responsibilities
Where fire stopping forms part of building work, building control in England will expect it to meet Approved Document B. For non-domestic premises and the common parts of multi-occupied residential buildings, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person, usually the owner, employer or managing agent, to carry out a fire risk assessment and maintain fire safety measures. Fire stopping and compartmentation are part of that.
Under the Building Safety Act 2022, building work on higher-risk buildings in England, broadly residential buildings at least 18 metres or seven storeys tall, requires approval from the Building Safety Regulator. The quality of fire stopping in such buildings receives close scrutiny.
Costs and surveys
Fire stopping penetrations typically cost from £25 each for straightforward sealing in accessible locations. Larger openings with many services, high level work, work above suspended ceilings and work in occupied buildings cost more. For existing buildings, a fire stopping survey identifies and records each penetration, and the remedial work is priced from that schedule. Combining fire stopping with other compartmentation work, such as upgrading walls or boxing steel, is usually more efficient than separate visits.
Keeping fire stopping intact
Fire stopping is only effective while it stays intact, which is why the biggest risk in an occupied building is future work. Every time an electrician, data installer or plumber runs a new service, there is a chance they cut through an existing seal. Building managers should make fire stopping part of the permit or briefing process for contractors, with a clear rule that any breach must be reinstated with a compatible tested product and recorded.
Periodic checks help too. Lift ceiling tiles in corridors and look at walls above the ceiling line, check risers and plant rooms, and compare what you find against the fire stopping records. Damaged seals, new unsealed holes and gaps where services have been removed should be added to the fire risk assessment action plan.
Questions people also ask
Can expanding foam be used for fire stopping?
Only fire-rated foam, and only within its tested scope for the wall, service and gap size involved. Ordinary expanding foam is not fire stopping and can burn. In many situations a different product, such as intumescent sealant, a fire collar or a fire batt, is the correct choice.
Who is responsible for fire stopping in a building?
During building work, the person carrying out the work must meet the Building Regulations. For non-domestic premises and the common parts of multi-occupied residential buildings, the responsible person under the Regulatory Reform (Fire Safety) Order 2005 must ensure fire safety measures, including fire stopping, are maintained.
How much does fire stopping cost?
Fire stopping penetrations typically cost from £25 each for straightforward work in accessible locations. Large openings with multiple services, high level or above-ceiling work, and work in occupied buildings cost more. A survey and schedule of penetrations allows an accurate price for a whole building.
Written and checked by the Fire Rated Walls team. Read our editorial policy.
More guides
How Much Does a Fire Rated Wall Cost in the UK?
A new fire rated stud partition in the UK typically costs £55–£85 per m² for 30 minutes and £75–£120 per m² for 60 minutes. Upgrading an existing…
30 vs 60 Minute Fire Rated Walls: Which Do You Need?
A 30 minute fire rated wall resists fire for at least 30 minutes, and is typical for protected stairways in houses, garage separation and many…
Loft Conversion Fire Protection: What the Rules Require
When a loft conversion adds a new storey to a typical house in England, Approved Document B normally requires a protected escape route from the new…
Integral Garage Fire Separation: Walls, Doors and Ceilings
The walls and ceiling between an integral or attached garage and the house should provide fire resistance, typically 30 minutes, with any door…
Get a free fire rated walls quote
Tell us what you need and we'll come back with a clear price.
Request a quote