Fire Rated Walls

Rochdale · North West

Fire Rated Walls in Rochdale

Fire rated walls in Rochdale are built to named manufacturer systems by insured local installers.

Get your Rochdale loft conversion fire protection sorted.

Free Fire Rated Walls quote in Rochdale

No obligation. We only use your details to reply about this job.

Rochdale and the surrounding area

Rochdale is in the Rochdale council area in the North West. Postcodes we cover here include OL11, OL12, OL16, OL10, OL15 and M24. The same team covers Littleborough, Milnrow, Whitworth and Newhey too.

Working in Rochdale

Rear extensions in Rochdale often include steel beams that need boxing in fire-resisting board. Integral garages in Rochdale family homes need fire-resisting walls and ceilings between garage and house.

Rows of solid-walled terraced houses are typical of the North West's mill towns, which brings its own issues with damp, access and parking. Older Rochdale houses converted into flats frequently need compartment walls and floors improved.

Guide prices for Rochdale

  • 60 minute stud partition: £75–£120 per m². Two layers of fire-resisting board each side with mineral wool where specified.
  • 30 minute stud partition: £55–£85 per m². Metal stud with fire-resisting board each side, taped and filled, typical domestic build.
  • Fire stopping penetrations: from £25 per penetration. Collars, sealant, batts or wraps depending on pipe, cable or duct size.

Prices are a guide. Your quote for Rochdale is a fixed price based on the details you give us. Full price guide.

Fire Rated Walls questions from Rochdale

Do you cover areas near Rochdale?

Yes. We arrange fire rated walls in Rochdale and nearby places including Royton and Chadderton, through specialists who work across Rochdale.

Do I need fire rated walls for my Rochdale loft conversion?

Usually, yes. Most loft conversions in Rochdale need the stairway protected with 30 minute walls, fire doors and interlinked alarms. Your Building Control approval from Rochdale or a registered building control approver sets out the requirements.

Does my Rochdale garage wall need to be fire rated?

If your garage is integral or attached, the wall and ceiling between it and your Rochdale home should be fire-resisting, typically 30 minutes, with a self-closing fire door.

Can you upgrade HMO walls in Rochdale?

Yes. HMO landlords in Rochdale use our network to upgrade walls onto escape routes, fit fire stopping and meet licensing or fire risk assessment requirements.

How do you make a wall 60 minutes fire rated?

A 60 minute wall is usually achieved with metal or timber studs boarded with two layers of fire-resisting plasterboard on each side, sometimes with mineral wool in the cavity. The exact build, including stud size, board thickness and screw spacing, must follow a manufacturer's tested system. Penetrations must be fire stopped to the same rating.

Does a loft conversion need fire rated walls?

In most two-storey houses, adding a loft room means the stairway must be protected to the exit, typically with 30 minute fire-resisting walls, fire doors onto the stair and interlinked smoke alarms. Some layouts use alternative solutions such as sprinklers, agreed with Building Control. Your approved plans will set out what is needed.

Get a free fire rated walls quote in Rochdale

Tell us what you need and we'll come back with a clear price.

Request a quote