Lancashire · North West
Fire Rated Walls in Lancaster
If your project in Lancaster or Heysham needs fire rated walls, we can match you with a specialist.
Where we work around Lancaster
We cover all of Lancaster and the wider Lancashire area. Jobs here are mostly in the LA1, LA2, LA5, LA6, LA3 and LA7 postcode areas. We also take jobs in Bolton-le-Sands, Caton, Hest Bank, Galgate and Slyne.
Fire Rated Walls in Lancaster: local know-how
Rows of solid-walled terraced houses are typical of the North West's mill towns, which brings its own issues with damp, access and parking. Victorian homes in Lancaster often have lath and plaster walls that need assessing or overboarding to achieve 30 minutes.
Loft conversions in Lancaster suburbs commonly need stair walls upgraded to 30 minutes and new fire doors. Suburban homes around Lancaster with open-plan conversions may need alternative fire strategies agreed with Building Control.
What we can do in Lancaster
HMO and Commercial Compartment Walls
Upgrading walls between bedrooms, flats, escape routes and commercial units to the fire resistance required by fire strategies.
Structural Steel Fire Protection
Boxing in steel beams and columns with fire-resisting board, or applying intumescent paint, to give 30 or 60 minutes protection.
Garage and Kitchen Separation Walls
Fire-resisting walls and ceilings between integral garages and the home, and around open-plan layouts where required.
Loft Conversion Fire Protection
Creating a protected stairway with 30 minute walls and fire doors so a loft conversion meets Building Regulations.
Fire Stopping and Penetration Sealing
Sealing every pipe, cable and duct that passes through a fire rated wall or floor with tested fire-stopping products.
Fire Rated Stud Partitions
New metal or timber stud walls built to tested 30, 60 or 120 minute systems using fire-resisting plasterboard.
Typical costs in Lancaster
- Upgrade existing wall to 30 minutes: £35–£65 per m². Overboarding an existing sound wall with fire-resisting plasterboard and sealing edges.
- 60 minute stud partition: £75–£120 per m². Two layers of fire-resisting board each side with mineral wool where specified.
- 30 minute stud partition: £55–£85 per m². Metal stud with fire-resisting board each side, taped and filled, typical domestic build.
Prices are a guide. Your quote for Lancaster is a fixed price based on the details you give us. Full price guide.
Fire Rated Walls questions from Lancaster
Can you upgrade HMO walls in Lancaster?
Yes. HMO landlords in Lancaster use our network to upgrade walls onto escape routes, fit fire stopping and meet licensing or fire risk assessment requirements.
Can you fire stop penetrations in Lancaster?
Yes. Specialists in Lancaster seal pipes, cables and ducts through fire rated walls with tested collars, sealants and batts, and provide photographic records for your files.
How do I get a fire rated wall quote in Lancaster?
Use our quote form with your Lancaster postcode, the wall's purpose, size and required rating. Drawings or Building Control notes help. A specialist will give you a fixed price.
How long does fire rated wall work take in Lancaster?
Most domestic fire rated walls in Lancaster take one to three days. Loft stair protection takes two to five days, and commercial projects vary with size and access.
Does a loft conversion need fire rated walls?
In most two-storey houses, adding a loft room means the stairway must be protected to the exit, typically with 30 minute fire-resisting walls, fire doors onto the stair and interlinked smoke alarms. Some layouts use alternative solutions such as sprinklers, agreed with Building Control. Your approved plans will set out what is needed.
Can I put a socket in a fire rated wall?
Yes, but the socket box breaks the fire-resisting board, so it must be protected. Common methods are intumescent putty pads behind the box or tested fire-rated back boxes. Back-to-back sockets should be offset. Without this, a socket can become a weak point where fire passes through the wall.
Helpful guides
Loft Conversion Fire Protection: What the Rules Require
When a loft conversion adds a new storey to a typical house in England, Approved Document B normally requires a protected escape route from…
Read the guide →Integral Garage Fire Separation: Walls, Doors and Ceilings
The walls and ceiling between an integral or attached garage and the house should provide fire resistance, typically 30 minutes, with any…
Read the guide →Get a free fire rated walls quote in Lancaster
Tell us what you need and we'll come back with a clear price.
Request a quote